- Temperature Controller
- Microcontroller Based
- Detection Principal of Melting Point
- Automatic by Silicon Photodiode
- Heating Media
- By Aluminum Block
- Temperature Range
- +5°C above ambient to 400°C
- Temperature Accuracy :
A) +5°C above ambient to 100°C ……… ±0.2°C
B) 101°C to 200°C …......………………………………… ±0.4°C
C) 200°C to 400°C ………......….…………………… ±0.5°C
- Readability
- 0.1°C
- Overheating Protection
- In-built - Set by user in method parameter
- Heating Before EMP* : Automatic heating depending upon temperature difference
(* EMP: Expected Melting Point)
- Heating Rate
- 1.0ºC/min
- Maximum Heating Time
- Around 6 minutes from 50°C to 350°C
- Maximum Cooling Time
- Around 6 minutes from 350°C to 50°C
- Detection of Melting :
A) Melting Point
B) Melting Range
- Type of Detection
- Auto / Manual (Color sample can be analysed by Manual detection)
- Melting Capillary Ports
- One sample at a time
- Detection of Boiling Point
- Manually by viewing in TFT Display
- Boiling Tube
- One
- Calibration
- Eight Calibration Standards (Six as per Pharmacopeia AND / OR Customer's known standards)
- Method
- 06 methods for Melting sample, 01 for Boiling sample and 1 for unknown sample with
View, Print & Delete facility.
- Temperature Sensor
- Duplex PT-100, One for internal use and One for calibration purpose by external Source
- Glass Melting Capillary
- OD: 1.4 to 1.6mm | ID: 1.0mm | Length: 100mm | One End Sealed
- Sample Filling Height
- 3mm
- Magnification
- 5x
- Viewing of Capillary
- Camera with TFT Display for viewing Melting Capillary and Boiling Tube in CAPillaryVIEW
- Display
- 20 x 4 Line Alphanumeric Backlit LCD
- Keypad
- Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
- Calibration Data Storage
- Non-Volatile Memory which can store, print & view calibration date & time, company name, standard name with temperature, actual reading of standard temperature, calibration done by, instrument serial number, instrument ID, model number etc.
- Analysis Data Storage : More than 500 analysis data can be stored with corresponding calibration data, analysis date & time, record number, Batch number / ID, sample name, username, assigned method number, MP1 (On set temperature) & MP2 (Clear temperature) reading of all three reading, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
(*: Not possible to enter data by instrument keypad but it will be handwritten)
- Searching of data
- With record number by scrolling.
- Report Formation
- As per Non-GLP Compliance
- Printer Interface
- Centronics Parallel Port / Serial (RS-232 C) Port
- Printer
- 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
- Power Supply
- 230 VAC ±10%, 50 Hz
- Melting Point Average Reading
- For three same sample
- Dimensions:
â— Net Dimension: 41 x 25 x 22 cm (L x W x H)
â— Gross Dimension: 48 x 33 x 35 cm (L x W x H)
- Weight:
â— Net Weight: 8 kg
â— Gross Weight: 10Â kg