Automatic Melting/Boiling Point Apparatus

Automatic Programmable Melting/Boiling Point Apparatus
With 21 CFR Part-11 Compliance

4.8 / 5 · 37 verified reviews

Model : µThermoCal100 | Make : ANALAB | HSN Code : 90278990

Supplied with Melting Capillary One End Sealed (Pack of 100 Nos.), Boiling Tube, Sample Tapping Rod, Two Melting Standards 49ºC and 238ºC, Forceps, Power Cord, ANALABsafe software, USB Interface Cable, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Share:
Temperature Controller
Microcontroller Based
Detection Principal of Melting Point
Automatic by Silicon Photodiode
Heating Media
By Aluminum Block
Temperature Range
+5°C above ambient to 400°C
Temperature Accuracy :
A) +5°C above ambient to 100°C ……… ±0.2°C
B) 101°C to 200°C …......………………………………… ±0.4°C
C) 200°C to 400°C ………......….…………………… ±0.5°C
Readability
0.1°C
Overheating Protection
In-built - Set by user in method parameter
Heating Before EMP* : Automatic heating depending upon temperature difference
(* EMP: Expected Melting Point)
Heating Rates
0.1 to 20.0ºC/min (Increment of 0.1ºC) - Adjustable
Maximum Heating Time
Around 6 minutes from 50°C to 350°C
Maximum Cooling Time
Around 6 minutes from 350°C to 50°C
Detection of Melting :
A) Melting Point
B) Melting Range
C) % Level of Melting Point between Melting Range
Type of Detection
Auto / Manual (Color sample can be analysed by Manual detection)
Melting Point Average Reading
For three same sample
Melting Capillary Ports
Three
Melting Channel
Three different sample analysis of different temperature in single run
Detection of Boiling Point
Manually by viewing in TFT Display
Boiling Tube
One
Calibration
Eight Calibration Standards (Six as per Pharmacopeia AND / OR Customer's known standards)
Method
40 methods for Melting sample, 10 for Boiling sample and 1 for unknown sample with View, Print & Delete facility.
Temperature Sensor
Duplex PT-100, One for internal use and One for calibration purpose by external Source.
Glass Melting Capillary
OD: 1.4 to 1.6mm | ID: 1.0mm | Length: 100mm | One End Sealed
Sample Filling Height
3mm
Magnification
5x
Recording of Melting Capillary
Camera with TFT Display for viewing and Recording of Melting Capillary in CAPillaryVIEW. Individual recording storage for each Capillary. (Last Analysis)
Display
20 x 4 Line Alphanumeric Backlit LCD
Keypad
Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
Calibration Data Storage
Non-Volatile Memory which can store, print & view company name, standard name, standard MP, observed MP, Calibration date and time, last calibration date & time, calibration done by, calibration status, instrument ID, serial number, model number etc.
Analysis Data Storage
More than 1500 analysis data can be stored with corresponding calibration data, analysis date & time, record number, Batch number / ID, sample name, username, assigned method number, MP1 (On set temperature) & MP2 (Clear temperature) reading of all three reading, instrument ID, serial number, model number, make, etc. Secondly, analysis data can be print online.
Searching of data
With record number, batch number/ID, date, date range and by scrolling.
Report Formation
As per GLP Compliance
21 CFR Part-11 Compliance :
● In-built with system for ease of operation without PC.
● 2 Admin, 10 Reviewers, 40 Users & 1 Manufacturer with individual Login ID & Passcode.
● Audit trail can store more than 5000 lines in instrument.
● Audit trail includes action taken, date & time, action taken by whom.
● Audit trail can be transfer to PC through ANALABsafe software and can print on 40 / 80 column dot matrix printer for record.
● Admins can set up operation permission of each Users & Reviewers.
● Strict Admins control to audit and monitor usage and access.
● Audit trail record can be printed with Date, Date Range and by individual User’s ID.
● Once Audit trail transfer to the PC or Printer, system will delete Audit trail records and before final deletion, the system will give warning twice.
● Data integrity with database capability to store Analysis Data, Calibration Data, Calibration and Analysis Method, Audit trail and Passcode in instrument.
● No direct access to data from outside the instrument, thereby creating a closed system.
● Audit traceability to ensure that the device and results are appropriately handled.
● Auto User’s logout after defined Logout time.
● Auto Users & Reviewers block when password is entered incorrectly 3 consecutive times
Printer Interface
Centronics Parallel Port / Serial (RS-232 C) Port
Printer
40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
PC Interface
USB Type - B
PC Connectivity
By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in GLP format, Calibration data and Audit trail from Instrument to PC in non-editable format (Cannot Delete)
Power Supply
230 VAC ±10%, 50 Hz
Dimensions:
● Net Dimension: 41 x 25 x 22 cm (L x W x H)
● Gross Dimension: 48 x 33 x 35 cm (L x W x H)
Weight:
● Net Weight: 8 kg
● Gross Weight: 10 kg
Download brochure

Testimonial video ready for playback.

Customer Testimonial
Analab Scientific Instruments