- Method of Detection
- Conductometric / Volumetric
- Range of Moisture Detection
- Better than 100 ppm to 100% (depends upon type of sample)
- Dispensing Resolution
- 0.01ml
- Magnetic Stirrer
- Built-in with soft touch Key speed controller
- Auto Neutralization
- On / Off - users selectable - reduces the time between analysis & gives accurate results
- Stirring Time
- 00:00 to 99:00 (mm:ss) – users adjustable
- End Point Sensitivity
- 80-100 - users adjustable
- End Point Time
- 1-20 seconds - users adjustable
- End Point mV
- 1000-3000 mV - users adjustable
- End Point Detection
- By Audio & Visual Alarm
- Over titration Alarm
- Audio / Visual Alarm at 15 ml to save KF Reagent
- Display of Reading
- Moisture in ppm & percentage (%)
- Auto Drain
- For cleaning reaction vessel - useful for large & multiple volume sample
- Flush
- For cleaning dispensing path
- Average KF Factor Calculation
- Manual
- Dispenser Calibration/Validation
- Onsite by users
- Dispenser MOC
- SS-316L & Teflon for Corrosion Protection & Maintenance Free Operation
- Dispenser Type
- Motorized - For accurate measurement
- Teflon Tube
- To transfer KF reagent from KF reagent bottle to dispenser & dispenser to reaction vessel
- Material of Construction
- Epoxy Based Powder Coated Metallic Body / GMP Enclosure made up of Stainless Steel
- Type of Electrode
- Dual Platinum - Combined Type
- Input
- Electrode with Banana Connector
- Error Messages
- “Over KF†& “KF Factor Error†& â€Low Memoryâ€
- Short Link
- Provided to diagnose the problem either with Instrument OR Electrode
- Display
- 16 x 2 Line Alphanumeric Backlit LCD
- Keypad
- Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
- Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, sample type, sample volume (ml / mg), sample density (for liquid sample), stirring time, end point time, end point sensitivity, end point in ml, moisture result in % & ppm, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
(*: Not possible to enter data by instrument keypad but it will be handwritten)
- Searching of data
- With record number by scrolling.
- Report Formation
- As per Non-GLP Compliance
- Printer Interface
- Centronics Parallel Port / Serial (RS-232 C) Port
- Printer
- 40 / 80 Column Dot Matrix Printer (Printer must procure optionally)
- Power Supply
- 230 VAC ±10%, 50 Hz
- Dimensions:
â— Net Dimension: 36 x 26 x 18 cm (L x W x H)
â— Gross Dimension: 42 x 36 x 32 cm (L x W x H)
- Weight:
â— Net Weight: 7.5 kg
â— Gross Weight: 10Â kg