Range of Moisture Detection : Better than 50 ppm to 100% (depends upon type of sample)
Dispensing Resolution : 0.001ml
Magnetic Stirrer : Built-in with soft touch Key speed controller
Calibration : Average factor can be calculated by
1) Water by volume
2) Water by weight
3) By DST
Method : 40 with Three pre-assigned methods
1) Liquid by volume
2) Liquid by weight
3) For Solid sample
Method No. 4-40 are customized with View, Print & Delete facility.
Auto Neutralization : On / Off - users selectable - reduces the time between analysis & gives accurate results
Stirring Time : 00:00 to 99:00 (mm:ss) – users adjustable
End Point Sensitivity : 80-100 - users adjustable
End Point Time : 1-20 seconds - users adjustable
End Point mV : 1000-3000 mV - users adjustable
End Point Detection : By Audio & Visual Alarm
Calibration Reminder Alarm : 0-99 Hours
Over titration Alarm : Audio / Visual Alarm at 15 ml to save KF Reagent
Display of Reading : Moisture in ppm, percentage (%), mg/ml of water, gm/L, Mol/L
Auto Drain : For cleaning reaction vessel - useful for large & multiple volume sample
Flush : For cleaning dispensing path
Calculation of % RSD : Possible
Average KF Factor Calculation : Automatic – Maximum 5 factor can be stored in memory.
Weight Entry : In Resolution of 0.1 mg / 0.01 mg – users selectable
Dispenser Calibration/Validation: Onsite by users
Dispenser MOC : SS-316L & Teflon for Corrosion Protection & Maintenance Free Operation
Dispenser Type : Motorized - For accurate measurement
Teflon Tube : To transfer KF reagent from KF reagent bottle to dispenser & dispenser to reaction vessel
Material of Construction : Epoxy Based Powder Coated Metallic Body / GMP Enclosure made up of Stainless Steel
Calibration Data Storage : Non-Volatile Memory which can store, print & view calibration date & time, calibration method, calibration done by, stirring time, average KF factor, % RSD, instrument serial number, instrument ID etc.
Analysis Data Storage : More than 750 analysis data, with corresponding calibration data company name, analysis date & time, record number, batch / ID number, sample name, username, sample type and method, sample volume (ml / mg), sample density (for liquid sample), stirring time, end point time, end point in ml, moisture result in %, ppm & H2O (mg / ml), analysis done on, instrument serial number, instrument ID etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
Searching of data : With record number, batch number/ID, date, date range and by scrolling.
Report Formation : As per GLP Compliance
Password Protection : Date & Time, Calibration Mode, Analysis Mode, Delete Stored Analysis Data and Delete Stored Analysis Method.
Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
Printer : 40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
Power Supply : 230 VAC ±10%, 50 Hz
Dimensions: â— Net Dimension: 36 x 26 x 18 cm (L x W x H) â— Gross Dimension: 42 x 36 x 32 cm (L x W x H)
Weight: â— Net Weight: 7.5 kg â— Gross Weight: 10Â kg