Supplied with Combination Glass pH Electrode (0-70ºC), Conductivity Cell K=1.0, Standard Buffer Tablets, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Share:
pH Range
-2.000 to 20.000 pH
Selectable Resolution
0.1 / 0.01 / 0.001 pH
Relative Accuracy
±0.02 / 0.002 pH
mV/ORP Range – mV/RmV
±2000.0
ORP
EH auto calibration to standard hydrogen electrode
Resolution
0.1
Relative Accuracy
±0.2 mV or 0.05%, whichever is greater.
Slope
80 - 120 %
Auto Buffer Recognition :
1) 6.86 / 7.00 & 4.01 / 9.18 / 10.01 pH @ 25ºC for two points
2) 4.01, 6.86 / 7.00 & 9.18 / 10.01 pH @ 25ºC for three points
Calibration Reminder Alarm
0-99 hours
Result
Auto / Manual
pH Buffer Standard
US / NIST / EURO / DIN
Short Link
Provided to diagnose the problem either with Instrument OR Electrode.
Conductivity Range :
● 0-20.00, 20-200.0, 200-2000 µS/cm, 2-20.000, 20-200, 200-2000 mS/cm for K=1.0
● 0-10.00, 10-100.0, 100-1000 µS/cm, 1-10.000, 10-100, 100-1000 mS/cm for K=0.5
● 0-2.00, 2-20.0, 20-200, 200-2000 µS/cm, 2-20, 20-200 mS/cm for K=0.1
(Range value change depending upon cell selection)
Conductivity Resolution
0.001, 0.01, 0.1 µS/cm & 0.001, 0.01, 0.1, 1 mS/cm
TDS Range : 0 to 10, 100, 1000, 10000 ppm, 100ppt, 1000ppt
(Depending on TDS Factor)
TDS Resolution
0.001, 0.01, 0.1 ppm & 0.001, 0.01, 0.1 ppt (1ppt=1000ppm)
Number of Range
Six
Calibration Standard
Six Conductivity & TDS Standard - One Per Range
Calibration Factor
Six – One Per Range
Range Selection
Auto / Manual
Suitable Cell Constant
0.1, 0.5 & 1.0 K
Adjustable Cell Constant
0.09 to 0.11 K, 0.45 to 0.55 K & 0.90 to 1.1 K
Conductivity to TDS Conversion
0.40000 to 1.00000 (Adjustable Factor)
Temperature Coefficient
Six - 0-10.000 % per °C (Adjustable) – One Per Range
Reading
Conductivity at actual temperature and at 25°C & TDS with scrolling display.
Temperature Range
-5.0 to 130.0°C
Temperature Resolution
0.1°C
Temperature Compensation
Auto / Manual
Temperature Calibration
In-built software and can be calibrated by users
Calibration & Analysis
pH Mode, ORP Mode, Conductivity Mode and TDS Mode.
Error Message
“Wrong standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range”, “Bad Buffer / Electrode”, “pH Over Range”, “Temperature Probe Error”, “In-complete Calibration”, “Calibration Due”, & “Low Memory”.
Display
16 x 2 Line Alphanumeric Backlit LCD.
Keypad
Membrane waterproof polyester soft keypad compliance to UL/ROHS.
Calibration Data Storage
Non-Volatile Memory can store, print & view calibration details.
Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, pH, mV, temperature reading, calibration data with date & time, conductivity at 25°C and conductivity at actual temperature, % Tempco, conductivity to TDS conversion factor, TDS, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
(*: Not possible to enter data by instrument keypad but it will be handwritten)
Searching of data
With record number, batch number, date, date range and by scrolling.
Report Formation
As per Non-GLP Compliance
Printer Interface
Centronics Parallel Port / Serial (RS-232 C) Port
Printer
40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
Power Supply
DC Adaptor
Dimensions:
● Net Dimension: 22 x 21 x 11 cm (L x W x H)
● Gross Dimension: 32 x 29 x 23 cm (L x W x H)
Weight:
● Net Weight: 1.5 kg
● Gross Weight: 3.5 kg