Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, ANALABsafe software, USB Interface Cable, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Share:
Conductivity Range :
● 0-20.00, 20-200.0, 200-2000 µS/cm, 2-20.000, 20-200, 200-2000 mS/cm for K=1.0
● 0-10.00, 10-100.0, 100-1000 µS/cm, 1-10.000, 10-100, 100-1000 mS/cm for K=0.5
● 0-2.00, 2-20.0, 20-200, 200-2000 µS/cm, 2-20, 20-200 mS/cm for K=0.1
(Range value change depending upon cell selection)
Conductivity Resolution
0.001, 0.01, 0.1 µS/cm & 0.001, 0.01, 0.1, 1 mS/cm
TDS Range : 0 to 10, 100, 1000, 10000 ppm, 100ppt, 1000ppt
(Depending on TDS Factor)
TDS Resolution
0.001, 0.01, 0.1 ppm & 0.001, 0.01, 0.1 ppt (1ppt=1000ppm)
Resistivity Range
20.00 MΩ to 50.00 KΩ, 5.00 KΩ, 500.00 Ω, 50.00 Ω, 0.50 Ω
Resistivity Resolution
0.001
Salinity
0.01 to 80000.0 ppm NaCl
Temperature Range
-5.0 to 130.0°C
Temperature Resolution
0.1°C
Temperature Compensation
Auto / Manual
Temperature Coefficient
Six - 0-10.000 % per °C (Adjustable) – One Per Range
Temperature Calibration
In-built software and can be calibrated by users
Number of Range
Six
Calibration Standard
Six Conductivity & TDS Standard - One Per Range
Calibration Factor
Six – One Per Range
Range Selection
Auto / Manual
Suitable Cell Constant
0.1, 0.5 & 1.0 K
Adjustable Cell Constant
0.09 to 0.11 K, 0.45 to 0.55 K & 0.90 to 1.1 K
Conductivity to TDS Conversion
0.40000 to 1.00000 (Adjustable Factor)
Reading
Conductivity at actual temperature and at 25°C, TDS, Resistivity & Salinity with scrolling display.
TDS Calibration & Analysis
In Separate Mode
Error Messages
“Wrong Standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try Lower Range”, “Temperature Probe Error” & “Low Memory”.
Display
20 x 4 Line Alphanumeric Backlit LCD.
Keypad
Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS.
Calibration Data Storage
Non-Volatile Memory which can store, print & view with calibration date & time, cell constant, calibration range, standard conductivity solution, measured conductivity at 25°C, actual temperature, calibration factor, instrument serial number, instrument ID, model number etc.
Analysis Data Storage
More than 1500 analysis data can be stored with corresponding calibration data with company name, analysis date & time, record number, batch number / ID, sample name, username, conductivity at 25°C and conductivity at actual temperature, % Tempco, conductivity to TDS conversion factor, TDS, resistivity, salinity, instrument serial number, instrument ID, model number etc. Secondly, analysis data can be print online.
Searching of data
With record number, batch number/ID, date, date range and by scrolling.
Report Formation
As per GLP Compliance
21 CFR Part-11 Compliance :
● In-built with system for ease of operation without PC.
● 2 Admin, 10 Reviewers, 40 Users & 1 Manufacturer with individual Login ID & Passcode.
● Audit trail can store more than 5000 lines in instrument.
● Audit trail includes action taken, date & time, action taken by whom.
● Audit trail can be transfer to PC through ANALABsafe software and can print on 40 / 80 column dot matrix printer for record.
● Admins can set up operation permission of each Users & Reviewers.
● Strict Admins control to audit and monitor usage and access.
● Audit trail record can be printed with Date, Date Range and by individual User’s ID.
● Once Audit trail transfer to the PC or Printer, system will delete Audit trail records and before final deletion, the system will give warning twice.
● Data integrity with database capability to store Analysis Data, Calibration Data, Audit trail and Passcode in instrument.
● No direct access to data from outside the instrument, thereby creating a closed system.
● Audit traceability to ensure that the device and results are appropriately handled.
● Auto User’s logout after defined Logout time.
● Auto Users & Reviewers block when password is entered incorrectly 3 consecutive times.
Printer Interface
Centronics Parallel Port / Serial (RS-232 C) Port
Printer
40 / 80 Column Dot Matrix Printer (Printer to be procure optionally)
PC Interface
USB Type - B
PC Connectivity
By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in GLP format, Calibration data and Audit trail from Instrument to PC in non-editable format (Cannot be Deleted)
Power Supply
DC Adaptor
Dimensions:
● Net Dimension: 22 x 21 x 11 cm (L x W x H)
● Gross Dimension: 32 x 29 x 23 cm (L x W x H)
Weight:
● Net Weight: 1.5 kg
● Gross Weight: 3.5 kg